[Q27-Q46] DumpExam NS0-592 Real Exam Question Answers Updated [Dec 09, 2021]

Share

DumpExam NS0-592 Real Exam Question Answers Updated [Dec 09, 2021]

Easily To Pass New Network Appliance NS0-592 Dumps with 67 Questions


NetApp NS0-592 Exam Topics:

SectionObjectives
ONTAP OS-Describe the tools available for support or troubleshooting
-Demonstrate knowledge of ONTAP cluster administration
-Demonstrate knowledge of data replication issues
-Describe the structure of ONTAP OS
-Demonstrate knowledge of how to troubleshoot ONTAP OS
-Demonstrate knowledge of how to handle panic events
Hardware-Demonstrate knowledge of hardware troubleshooting
-Demonstrate knowledge of troubleshooting SP or BMC
-Describe the hardware components in a Fibre Channel environment
-Demonstrate knowledge of the cluster interconnect infrastructure
-Describe MetroCluster configurations


NetApp NS0-592 Exam Certification Details:

Exam NameSupport Engineer ONTAP Specialist
Exam Price$150 USD
Exam RegistrationPEARSON VUE
Sample QuestionsNetApp NS0-592 Sample Questions
Exam CodeNS0-592 NCSE ONTAP
Passing Score62%

 

NEW QUESTION 27
End users are complaining of high latency when accessing an ONTAP 9 luster.
Which command helps you to determine whether there is a storage component that is contributing to this problem?

  • A. qos statistics latency show
  • B. sysstat -c 30 -M 1
  • C. wafltop show -v -cpu -I 10 -c 5-n 6
  • D. qos statistics performance show

Answer: D

 

NEW QUESTION 28
A field support engineer has just replaced the IOXM on NODE2 on a FAS8080 running ONTAP 9.1. After the replacement, the customer is unable to perform a giveback because the interconnect is down.
In this scenario, which statement is correct?

  • A. Verify that the interconnect cables on the IOXM are connected correctly.
  • B. Verify that there cross-links between the interconnects.
  • C. Verify that the interconnect cables on the motherboard are connected correctly.
  • D. Verify that the installed FC-VI cards are configured properly.

Answer: A

 

NEW QUESTION 29
A reboot was performed by a watchdog reset on the node.
In this scenario, which statement is true?

  • A. In case of an L2 watchdog event, determine whether a core was dumped.
  • B. The wafl_check command should be executed.
  • C. The service processor no longer responds.
  • D. In case of an L1 watchdog event, determine whether a panic message was recorded.

Answer: C

 

NEW QUESTION 30
A non-maskable interrupt event occurs. The system panics and then reboots.
In this scenario, what would have caused the panic?

  • A. a secd process
  • B. a watchdog timer
  • C. an ICMP blackhole detector
  • D. a volume location distributed database

Answer: B

 

NEW QUESTION 31
A customer complains that the copy offload does not work when copying large file from a Windows 8 client between the CIFS shares that are hosted on the same ONTAP cluster.
What are two reasons for this problem? (Choose two.)

  • A. The client should be using Windows 10 for ODX support.
  • B. The source and target volumes reside on different cluster nodes.
  • C. SMB 3.0 disabled on the CIFS SVM.
  • D. Deduplication is not enabled on the destination volume.

Answer: C,D

 

NEW QUESTION 32
A customer reports that OnCommand Performance Manager shows that the workload on node-02 in a 4-node cluster has increased to a level that is higher than the threshold. The customer wants to avoid this issue becoming a performance problem.
Which two actions would result in achieving this goal? (Choose two.)

  • A. Use the volume move command to move one or more volumes to another aggregate that is owned by another node that is less utilized.
  • B. Use the storage aggregate relocation command to offload an aggregate to its partner.
  • C. Use the storage aggregate scrub command to verify the parity on the busy aggregates.
  • D. Physically move the shelf to another node that is less utilized.

Answer: A,D

 

NEW QUESTION 33
A customer called you after a failure in their Microsoft Hyper-V environment on the "SVM1" SVM. The customer wants to enable nondisruptive operations (NDO) to prevent future failures.
In this scenario, which two actions must be performed? (Choose two.)

  • A. Verify that SMB2 is enabled.
  • B. Verify that the continuously-available option is set on the CIFS share.
  • C. Verify that the branchcache option is set on the CIFS share.
  • D. Verify that SMB3 is enabled.

Answer: A,B

 

NEW QUESTION 34
Click the exhibit button.

A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?

  • A. The problem is due to a difference in operation size.
  • B. Perfstat should be used to explain the behavior.
  • C. A case with NetApp should be raised to find the root cause.
  • D. There are operation types that are not listed in the output.

Answer: A

 

NEW QUESTION 35
Click the exhibit button.

You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)

  • A. storage bridges BrB1
  • B. FC switch SwA1
  • C. FC switch SwB1
  • D. FC switch SwA2
  • E. ISL cables

Answer: B,C,E

 

NEW QUESTION 36
Click the exhibit button.

A customer reports that their system recently began logging an error.
Referring to the exhibit, which two statements are correct? (Choose two.)

  • A. The spmd application failed to restart the ntpd daemon.
  • B. A user is attempting to restart the ntpd daemon.
  • C. The bcomd application is responsible for monitoring the observed behavior.
  • D. The ntpd daemon is responsible for time services.

Answer: B,D

 

NEW QUESTION 37
Click the exhibit button.

A storage administrator reports that when they enabled Vscan, they began receiving reports of CIFS users having very slow access to all their files. The storage administrator recovered from the issue by disabling Vscan on their SVM. The storage administrator was able to collect perfstat output during the time of the reported slow access, as shown in the exhibit.
In this situation, what is the problem?

  • A. The problem is on the SVM, as shown in the scan_latency output.
  • B. Vscan server 192.168.100.144 was slower than Vscan server 10.23.23.54 in completing Vscan requests.
  • C. The problem was with both Vscan servers 192.168.100.144 and 10.23.23.54.
  • D. Vscan server 10.23.23.54 was slower than Vscan server 192.168.100.144 in completing Vscan requests.

Answer: B

 

NEW QUESTION 38
Click the exhibit button.

A customer reports that when they are failing over Hyper-V VMs, the process fails, and the server reports an error that indicates that there is something wrong with the storage.
Referring to the exhibit, which three actions would be required in ONTAP to solve this problem? (Choose three.)

  • A. Verify that the oplocks share property is configured.
  • B. Verify that the continuously -available share parameter is configured.
  • C. Verify that -offline-files parameter is set to manual on the share.
  • D. Verify that the -symlink-properties parameter is enabled on the share.
  • E. Verify that the access-based-enumeration share parameter is configured.

Answer: A,B,E

 

NEW QUESTION 39
In a 4-node MetroCluster cluster, both clusters are alerting that the connection to an ATTO bridge is lost.
Which three components should be verified to determine what is causing this problem? (Choose three.)

  • A. the ATTO bridge
  • B. the SFPs that are connecting the ATTO bridge to the switch
  • C. the SFPs in the storage controllers
  • D. the fiber cable that is connecting the ATTO bridge to the switch
  • E. the dark fiber cables between sites

Answer: A,B,D

 

NEW QUESTION 40
Click the exhibit button.

A volume move operation has been initiated to move a volume named MirrScr from one aggregate to another.
The operation failed with the error that is shown in the exhibit.
In this scenario, which statement is correct?

  • A. There are too many snapshots on the source volume.
  • B. The volume move cannot be completed at this time because of high use in this node.
  • C. Manually trigger the cutover process in order to restart the job.
  • D. Cancel and restart the volume move operation.

Answer: C

 

NEW QUESTION 41
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?

  • A. Use the storage pool create command.
  • B. Use the volume size command.
  • C. Use the volume create command.
  • D. Use the Deploy utility to provision the FlexGroup volume.

Answer: A

 

NEW QUESTION 42
Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.
In this scenario, what is the reason for the behavior?

  • A. The volume move command uses the intercluster LIFs, not the data LIFs.
  • B. The volume move command uses the HA iWarp interconnect, not the client access switches.
  • C. The volume move command uses copy offload protocol, so it does not show up when monitored.
  • D. The volume move command uses the cluster interconnect switches, not the client access switches.

Answer: C

 

NEW QUESTION 43
Click the exhibit button.

When you log in to a node, a warning is displayed as shown in the exhibit.
Which statement is correct in this scenario?

  • A. One or more RDB db files are damaged due to an internal software error.
  • B. The node cannot communicate with the rest of the nodes in the cluster.
  • C. The node root volume was moved to a new aggregate.
  • D. The partner still hosts the CFO aggregate for the node.

Answer: B

 

NEW QUESTION 44
Click the exhibit button.

You have just cabled a new shelf to a FAS8200. Running the system node run -node * sysconfig - a command indicates that multipath HA is configured. However, after running Config Advisor, you receive an error that your cabling is incorrect.
As indicated in the exhibit, which two actions will correct the cabling? (Choose two.)

  • A. Move the 0b SAS connection on the top controller to 0d on the top controller.
  • B. Move the 0b SAS connection on the bottom controller to 0d on the bottom controller.
  • C. Move the 0b SAS connection on the top controller to 0d on the bottom controller.
  • D. Move the 0b SAS connection on the bottom controller to 0d on the top controller.

Answer: A,B

 

NEW QUESTION 45
When you issue a volume clone create command, which entity in WAFL is copied?

  • A. the vol_info block
  • B. the buftree
  • C. the inode file
  • D. the data block

Answer: C

 

NEW QUESTION 46
......

Latest NS0-592 Study Guides 2021 - With Test Engine PDF: https://www.dumpexam.com/NS0-592-valid-torrent.html